High quality Very first,and Consumer Supreme is our guideline to offer the most beneficial service to our consumers.At present, we're attempting our greatest to be among the top exporters in our area to fulfill buyers far more need to have for Bipolar Coagulator, Neonatal Ventilator Circuit, Monopolar Cautery Pencil, We warmly welcome all perspective inquiries from home and abroad to cooperate with us, and look forward to your correspondence.
High definition Invasive Blood Pressure Transducer - Disposable Pressure Transducer – Hisern Detail:

Product Display

Disposable Pressure Transducer

Disposable pressure transducer is for the continuous measurement of physiological pressure and determination of other important haemodynamic parameters. Hisern’s DPT can provide accurate and reliable blood pressure measurements of arterial and venous during cardiac intervention operations.

Indicated for pressure monitoring applications like:

● Arterial blood pressure (ABP)
● Central venous pressure (CVP)
● Intra cranial pressure (ICP)
● Intra abdominal pressure (IAP)

Features & Benefits

Flushing Device

● Micro-porous flushing valve, flushing at constant flow rate, to avoid coagulation in the pipeline and to prevent waveform distortion
● Two flow rates of 3ml/h and 30ml/h (for neonates) are both available
● Can be washed by lifting and pulling, easy to operate

Special Three-way Stopcock

● Flexible switch, convenient for flushing and emptying
● Available with closed blood sampling system, reducing the risk of nosocomial infections
● Automatic flushing to prevent coagulation and bacterial colonization

Complete Specifications

● Various models can meet different needs, such as ABP, CVP, PCWP, PA, RA, LA, ICP, etc
● 6 kinds of connectors are compatible with most brands of monitors in the world

Configuration

● Multi-color labels , clear instructions to monitor blood pressure
● Provide white non-porous cap to replace to avoid nosocomial infection
● Optional sensor holder, can fix multiple transducers.
● Optional adapter cable, compatible with monitors of various brands

Application Scenario

● ICU
● Operating Room
● Emergency Room
● Cardiology Department
● Anesthesiology Department
● Intervention Therapy Department

Parameters

ITEMS MIN TYP MAX UNITS NOTES
Electrical Operating Pressure Range -50 300 mmHg
Over Pressure 125 psi
Zero Pressure Offset -20 20 mmHg
Input Impedance 1200 3200
Output Impedance 285 315
Output Symmetry 0.95 1.05 Ratio 3
Supply Voltage 2 6 10 Vdc or Vac rms
Risk Current (@ 120 Vac rms, 60Hz) 2 uA
Sensitivity 4.95 5.00 5.05 uU/V/mmHg
Performance Calibration 97.5 100 102.5 mmHg 1
Linearity and Hysteresis (-30 to 100 mmHg) -1 1 mmHg 2
Linearity and Hysteresis (100 to 200 mmHg) -1 1 % Output 2
Linearity and Hysteresis (200 to 300 mmHg) -1.5 1.5 % Output 2
Frequency Response 1200 Hz
Offset Drift 2 mmHg 4
Thermal Span Shift -0.1 0.1 %/°C 5
Thermal Offset Shift -0.3 0.3 mmHgC 5
Phase Shift (@ 5KHz) 5 Degrees
Defibrillator withstand (400 joules) 5 Discharges 6
Light Sensitivity (3000 Foot Candle) 1 mmHg
Enviromental Sterilization (ETO) 3 Cycles 7
Operating Temperature 10 40 °C
Storage Temperature -25 +70 °C
Operating Product Life 168 Hours
Shelf Life 5 Years
Dielectric Breakdown 10,000 Vdc
Humidity (External) 10-90% (non-condensing)
Media Interface Dielectric Gel
Warm-Up Time 5 Seconds

Product detail pictures:

High definition Invasive Blood Pressure Transducer - Disposable Pressure Transducer – Hisern detail pictures

High definition Invasive Blood Pressure Transducer - Disposable Pressure Transducer – Hisern detail pictures

High definition Invasive Blood Pressure Transducer - Disposable Pressure Transducer – Hisern detail pictures


Related Product Guide:

We now have our own gross sales team, style and design workforce, technical crew, QC workforce and package group. We now have strict quality manage procedures for each system. Also, all of our workers are experienced in printing industry for High definition Invasive Blood Pressure Transducer - Disposable Pressure Transducer – Hisern , The product will supply to all over the world, such as: azerbaijan, Swiss, Portugal, Each year, many of our customers would visit our company and achieve great business advancements working with us. We sincerely welcome you to visit us at any time and together we will prevail to a greater success in the hair industry.
  • The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Mona from Gabon - 2017.03.28 12:22
    It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Adelaide from Tanzania - 2018.12.14 15:26
    Write your message here and send it to us