Good Quality Hme Filter Ventilator - Disposable Bacterial and Viral Filter – Hisern
Good Quality Hme Filter Ventilator - Disposable Bacterial and Viral Filter – Hisern Detail:
Detail
Disposable Bacterial and Viral Filter is used for bacteria, particle filtration in breathing machine and anesthesia machine and to increase the gas moisture degree, also can be equipped with pulmonary function machine to filter the spray with bacterial from the patient. Hisern’s Bacterial/Filter media was tested to VFE Efficiency 99.99% and BFE Efficiency 99.999% ASTM Standards by Nelson Laboratory. Filter efficiency may vary during use and should be replaced if filter becomes visibly soiled, resistance to flow reaches an unacceptable limit or after 24 hours of active use.
Product Benefits
● Effectively filter bacteria, saliva, viruses, secretions, dust, etc
● Prevent cross infection, reduce nosocomial infections
● Lightweight, reducing patient-side traction
Normal Filter
Heat Moisture Exchanger Filter (HMEF)
Disposable Bacterial and Viral Filter
Features
● Compatible to all kinds of ISO-standard tube
● Low Breathing resistance
● Block particles, bacteria and other pathogens in
● Anesthesia and breathing circuit from entering the
● Respiratory system
● VFE≥99.99% BFE≥99.999%
● Lightweight, reducing torque on tracheal connection
● Gas sampling port with cap for easy, safe monitoring
● Of expired gases
● Transparent shell for good visualization of any
● Potential blockage
Parameters
Description | Bacterial/Viral Filter (BV) |
Humidity Output | N/A |
Filtration Efficiency | BFE 99.9-99.999 % ,VFE 99-99.99% |
Resistance @ 30 LPM |
<1.2cmH2O, (BFE99.999%,VFE 99.99% ) |
<0.6cmH2O, ( BFE 99.9%, VFE 99% ) | |
Resistance @ 60 LPM |
<2.6 cmH2O, ( BFE 99.999%, VFE 99.99% ) |
<1.5 cmH2O, ( BFE 99.9%, VFE 99% ) | |
Dead space | 32ml |
Tidal Volume Range | 250-1500ml |
Connections | 22M/15F-15M/22F |
Gas Monitoring Luer Port with retainer strap | Yes |
Weight | 25±3g |
Disposable Bacterial and Viral Filter
Heat and Moisture Exchanger Filter combines the efficiency of dedicated breathing filters with optimum moisture return.
Features
● Lightweight, reducing additional weight on the tracheal connection. Maximizes the humidity of inspired gases
● No need to heat and moisten
● Luer Port and Cap
Parameters
Description | Adult Type | Pediatric Type | |
HMEF | HMEF with Contra Angle | HMEF | |
Humidity Output | 31mg/ H2O@ VT 500ml | ||
Filtration Efficiency | BFE 99.9-99.999%,VFE 99-99.99% | ||
Resistance @ 20 LPM | / | <1.8cmH2O, ( BFE 99.999 %, VFE 99.99%) | |
<1.0 cmH2O, ( BFE 99.9%, VFE 99%) | |||
Resistance @ 30 LPM | <1.5cmH2O, ( BFE 99.999%, VFE 99.99% ) | / | |
<0.8cmH2O, ( BFE 99.9%, VFE 99% ) | |||
Resistance @ 60 LPM | <3.1cmH2O, ( BFE 99.999 %, VFE 99.99% ) | ||
<1.8 cmH2O, (BFE 99.9%, VFE 99% ) | |||
Dead space | 45ml | 20ml | |
Tidal Volume Range | 150-1500ml | 150-300ml | |
Connections | 22M/15F-22F/15M | ||
Gas Monitoring Luer Port with retainer strap | Yes | ||
Weight | 26.5±3g | 16 ±3g |
Product detail pictures:
Related Product Guide:
As a way to provide you advantage and enlarge our organization, we even have inspectors in QC Crew and guarantee you our greatest assistance and product or service for Good Quality Hme Filter Ventilator - Disposable Bacterial and Viral Filter – Hisern , The product will supply to all over the world, such as: United States, Ottawa, Mecca, We sincerely hope to cooperate with customers all over the world, if you would like to have more information, make sure you kindly contact us, we have been looking forward to building up a great business relationship with you.
By Arlene from Sevilla - 2017.03.28 12:22
This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
By Delia Pesina from Uruguay - 2017.05.02 11:33